Siemens SINUMERIK 840C User Manual
Page 664

Display
09.95
Siemens AG 2001
All Rights Reserved
6FC5197–
j
AA50
9–43
SINUMERIK 840C (IA)
Note
The displayed measurement results can be stored as a file on the MMC by selecting
softkey File functions.
Data output of
Data can be output on an external PC via the V24 interface and
circularity test
by means of commands in the “Services” menu. The extensions for “Services”
measurement results
required for this purpose are listed in the requirements to other areas. Data can
therefore be output in PC format with the aid of the “PC-IN” program. Within this
program, it is possible to re-convert the data back to the original ASCII format
with software version 3.0 and higher.
Note
Measurement results can also be written to a file using the hardcopy function and
output by means of “Services” functions.
SW 5
You can switch to graphic representation of the contour with this softkey.
Fig. 9.19
Explanation
The contour is shown without any distortion if the value 0 is entered in the field
“Resolution”. If suitable radius and feedrate values are entered, other contours
can also be displayed.
Radius and feedrate represent the input parameters required for setting the mea-
suring duration and the radius is used to define the form of graphic representa-
tion.
Note
Storage and output of the measuring results are the same as described for the
circularity test display in Section 9.5.2.
9 Drive Servo Start-Up Application (as from SW 3)
9.5.2 Circularity test (option – SW 4)