6 NC Machine Data (NC MD), NC Setting Data (NC SD)
12.93
6.6.1 General MD bits (general bits)
7
6
5
4
3
2
1
0
Bit No.
NC MD
5141
to
5146
Ethernet address
The Ethernet address is the address of the bus interface module within the network.
Active:
On POWER ON
NC MD
Ethernet address
(Binary)
Byte
Decimal
Default value
5141
0 0 0 0
1 0 0 0
Byte 1
08
0 0 0 0
1 0 0 0
5142
0 0 0 0
0 0 0 0
Byte 2
00
0 0 0 0
0 0 0 0
5143
0 0 0 0
0 1 1 0
Byte 3
06
0 0 0 0
0 1 1 0
5144
0 0 0 0
0 0 0 1
Byte 4
01
0 0 0 0
0 0 0 1
5145
User assignable
Byte 5
User assignable
0 0 0 0
0 0 0 0
5146
User assignable
Byte 6
User assignable
0 0 0 0
0 0 0 0
The last four bits in the Ethernet address are for the bus interface module.