Siemens SINUMERIK 840C User Manual
Page 509

7 Drive Machine Data (SIMODRIVE Drive MD)
07.97
7.3.2 Drive MD (data description)
Motor no-load voltage
1135
Default value
Lower input limit
Upper input limit
Units
0.0
0.0
500.0
V
Active
at once*
Input of motor no-load voltage as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 1102).
Note:
This data is relevant only for MSD drives.
* Active on "Power On" until SW < 6
Motor no-load current
1136
Default value
Lower input limit
Upper input limit
Units
0.0
0.0
500.0
A
Active
at once*
Input of motor no-load current as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 1102).
Note:
This data is relevant only for MSD drives.
* Active on "Power On" until SW < 6
Stator resistance cold
1137
Default value
Lower input limit
Upper input limit
Units
0.0
0.0
120.0
Active
at once*
Input of stator resistance (cold) as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 1102).
Note:
This data is relevant only for MSD drives.
* Active on "Power On" until SW < 6
Rotor resistance cold
1138
Default value
Lower input limit
Upper input limit
Units
0.0
0.0
120.0
Active
at once*
Input of rotor resistance (cold) as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 1102).
Note:
This data is relevant only for MSD drives.
* Active on "Power On" until SW < 6
7–94
©
Siemens AG 1992 All Rights Reserved 6FC5197- AA50
SINUMERIK 840C (IA)