6 NC Machine Data (NC MD), NC Setting Data (NC SD)
01.99
6.12.1 NC setting data (NC SD)
Setting data for the additive protection zone adaptation (as from SW 6)
The values for the coordination of the dynamic protection zone adaptation are to be entered in
the following setting data bits:
SD
No.
Description
Default
value
Maximum
input value
Reference
system
Input unit
800*
Protection zone enlargement in X+ direction
0
9999 9999
IS
–
804*
Protection zone enlargement in Y+ direction
0
9999 9999
IS
–
808*
Protection zone enlargement in Z+ direction
0
9999 9999
IS
–
812*
Protection zone enlargement in X- direction
0
9999 9999
IS
–
816*
Protection zone enlargement in Y- direction
0
9999 9999
IS
–
820*
Protection zone enlargement in Z- direction
0
9999 9999
IS
–
These setting data are activated by MD 3876* bit 1.
6.13
Cycles machine data
The cycles machine data are active only when you use the measuring cycles from Version 20.
For a detailed description of the cycles machine data please refer to the
Start-up Guide
Measuring Cycles, Versions 20 and 30
END OF SECTION