7 Drive Machine Data (SIMODRIVE Drive MD)
10.94
7.1.2 MSD MD (data description - SW 3)
Minimum value min/max memory
182
Default value
Lower output limit
Upper output limit
Units
–
0000
–
Hex
Active
at once
Output of minimum value of a previously defined variable (see MD 181). The value is displayed
in hexadecimal format.
Maximum value min/max memory
183
Default value
Lower output limit
Upper output limit
Units
–
0000
–
Hex
Active
at once
Output of maximum value of a previously defined variable (see MD 181). The value is
displayed in hexadecimal format.
Address for monitoring 1
185
Default value
Lower input limit
Upper input limit
Units
0C06
0000
FFFF
Hex
Active
at once
Input of address 1 to be monitored for variable relay function 1.
Threshold for monitoring 1
186
Default value
Lower input limit
Upper input limit
Units
0000
0000
FFFF
Hex
Active
at once
Input of threshold value 1 of address 1 to be monitored for variable relay function 1.
ON-delay monitoring 1
187
Default value
Lower input limit
Upper input limit
Units
0
0
10.00
s
Active
at once
Input of ON-delay 1 of address 1 to be monitored for variable relay function 1.
Drop delay monitoring 1
188
Default value
Lower input limit
Upper input limit
Units
0
0
10.00
s
Active
at once
Input of drop delay 1 of address 1 to be monitored for variable relay function 1.
7–24
©
Siemens AG 1992 All Rights Reserved 6FC5197- AA50