Siemens SINUMERIK 840C User Manual
Page 508

04.96
7 Drive Machine Data (SIMODRIVE Drive MD)
7.3.2 Drive MD (data description)
cos
power factor
1129
Default value
Lower input limit
Upper input limit
Units
0.8
0.0
1.0
Active on
Power On
cos
is required for the calculation of the equivalent circuit diagrams from the data on the
rating plate.
Note:
This machine data only applies to main spindle drives.
Motor rated power
1130
Default value
Lower input limit
Upper input limit
Units
0.0
0.0
1 500.0
kW
Active on
Power On
Input of motor rated power as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 96).
Note:
This data is relevant only for MSD drives.
Motor rated voltage
1132
Default value
Lower input limit
Upper input limit
Units
380.0
0.0
5 000.0
V
Active on
Power On
Input of motor rated voltage as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 1102).
Motor rated frequency
1134
Default value
Lower input limit
Upper input limit
Units
50.0
0.0
3 000.0
Hz
Active on
Power On
Input of motor rated frequency as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 1102).
Note:
This data is relevant only for MSD drives.
©
Siemens AG 1992 All Rights Reserved 6FC5197- AA50
7–93