Siemens SINUMERIK 840C User Manual
Page 466

12.93
7 Drive Machine Data (SIMODRIVE Drive MD)
7.2.2 FDD MD (data description - SW 3)
Order No.
Rated
speed
Motor
code no.
n
rated
in
rev/min
1FT6132-6AF7X-XXXX
3000
1212
1FT6061-6AH7X-XXXX
4500
1301
1FT6062-6AH7X-XXXX
4500
1302
1FT6064-6AH7X-XXXX
4500
1303
1FT6081-8AH7X-XXXX
4500
1304
1FT6082-8AH7X-XXXX
4500
1305
1FT6084-8AH7X-XXXX
4500
1306
1FT6086-8AH7X-XXXX
4500
1307
1FT6102-8AH7X-XXXX
4500
1308
1FT6031-6AK7X-XXXX
6000
1401
Order No.
Rated
speed
Motor
code no.
n
rated
in
rev/min
1FT6034-6AK7X-XXXX
6000
1402
1FT6041-6AK7X-XXXX
6000
1403
1FT6044-6AK7X-XXXX
6000
1404
1FT6061-6AK7X-XXXX
6000
1405
1FT6062-6AK7X-XXXX
6000
1406
1FT6064-6AK7X-XXXX
6000
1407
1FT6081-8AK7X-XXXX
6000
1408
1FT6082-8AK7X-XXXX
6000
1409
1FT6084-8AK7X-XXXX
6000
1410
Motor rated current
1103
Default value
Lower input limit
Upper input limit
Units
1.0
0.0
500
A
Active
at once
Input of rated current consumption (RMS value) in operation at rated torque and rated speed
as specified on the motor data sheet (non-Siemens motor) or automatic parameterization using
machine data "Motor code number" (MD 1102).
Maximum motor current
1104
Default value
Lower input limit
Upper input limit
Units
2.0
0.0
500
A
Active on
Power On
Input of maximum permissible motor current (RMS value) as specified on the motor data sheet
(non-Siemens motor) or automatic parameterization using machine data "Motor code number"
(MD 1102). To ensure reliable monitoring and limitation, the setting in this machine data should
not be reduced (see also MD 1105).
Reduction of maximum motor current
1105
Default value
Lower input limit
Upper input limit
Units
100
0
100
%
Active
at once
Input of reduction factor for the maximum permissible motor current. The maximum motor
current (MD 1104) is the reference value for the specified percentage.
©
Siemens AG 1992 All Rights Reserved 6FC5197- AA50
7–51
SINUMERIK 840C (IA)