7 Drive Machine Data (SIMODRIVE Drive MD)
10.94
7.1.2 MSD MD (data description - SW 3)
Selection I/f control
313
Default value
Lower input limit
Upper input limit
Units
0
0
1
Hex
Active
at once
The I/f control diagnosis aid is activated by entering bit 0 = 1. This control is used to check
encoder faults. A variable speed (without encoder evaluation) can be specified via MD 311
(current) and MD 312 (frequency).
Bit 0
Activate I/f control
Bit 1-15
Not assigned
Display P-gain current controller
316
Default value
Lower output limit
Upper output limit
Units
–
–
–
–
Active
at once
Display machine data for the current controller P gain. The current controller P gain is
calculated according to the motor, converter and converter switching frequency and can be
corrected by an offset in machine data MD 116 (P-gain current controller motor 1) and MD 278
(P-gain current controller motor 2). The resulting value is displayed in MD 316. When the star-
delta switchover function is enabled, the display is referred to the currently active operating
mode.
Creep speed angle controller
337
Default value
Lower input limit
Upper input limit
Units
300
0
600
rev/min
Active
at once
Input of creep speed of angle controller. At speeds above the value entered here, the I-action
component of the phase current controllers is disabled and the angle controller of the FCS
(Frequency-Compensated Spindle drive) control enabled.
Hysteresis MD 337
338
Default value
Lower input limit
Upper input limit
Units
25
0
256
rev/min
Active
at once
Input of hysteresis for creep speed in MD 337. The value corresponding to half the hysteresis
width in rev/min must be entered.
Data version
399
Default value
Lower output limit
Upper output limit
Units
–
0
65 535
–
Active
at once
Display machine data for the data version of the machine data set.
7–46
©
Siemens AG 1992 All Rights Reserved 6FC5197- AA50