Siemens SINUMERIK 840C User Manual
Page 451

7 Drive Machine Data (SIMODRIVE Drive MD)
10.94
7.1.2 MSD MD (data description - SW 3)
Programmable message 2
242
Default value
Lower input limit
Upper input limit
Units
3
1
20
–
Active
at once
A function can be assigned to programmable message 2 in this machine data.
The default setting corresponds to M
d
> M
dx
(see MD 241 for other settings).
Programmable message 3
243
Default value
Lower input limit
Upper input limit
Units
1
1
20
–
Active
at once
A function can be assigned to programmable message 3 in this machine data.
The default setting corresponds to n
act
< n
min
(see MD 241 for other settings).
Programmable message 4
244
Default value
Lower input limit
Upper input limit
Units
4
1
20
–
Active
at once
A function can be assigned to programmable message 4 in this machine data.
The default setting corresponds to n
act
< n
x
(see MD 241 for other settings).
Programmable message 5
245
Default value
Lower input limit
Upper input limit
Units
20
1
20
–
Active
at once
A function can be assigned to programmable message 5 in this machine data.
The default setting corresponds to variable relay function 1 (MD 185, see MD 241 for other
settings).
Programmable message 6
246
Default value
Lower input limit
Upper input limit
Units
7
1
20
–
Active
at once
A function can be assigned to programmable message 6 in this machine data.
The default setting corresponds to variable relay function 2 (MD 190, see MD 241 for other
settings).
7–36
©
Siemens AG 1992 All Rights Reserved 6FC5197- AA50
SINUMERIK 840C (IA)