Siemens SINUMERIK 840C User Manual
Page 217

6 NC Machine Data (NC MD), NC Setting Data (NC SD)
09.95
6.3 Channel-specific MD (channel data)
Reset state G group
108*-122*
Default value
Lower input limit
Upper input limit
Units
see below
see table of input
values
see table of input
values
–
Active in block
prior
to
decodg
The reset state for G groups 1, 3, 6, 8, 12, 15 and 25 may be defined on a channel-specific
basis.
Only those G functions shown in the table below may be specified in NC MD 108* to 122* for
the relevant G group.
The reset state for G group 9 (G70/G71) is defined together with the input resolution in
NC MD 5002.
Default value
T
M
G group
108*
1
1
1
110*
18
17
3
112*
54
54
6
114*
64
60
8
116*
0
0
9
118*
95
94
12
120*
150
150
15
122*
450
450
1)
25
Table of input values
Internal
G group
G functions
0
00
MD
01
M/T
MD
10
MD
11
MD
02
MD
03
MD
33
MD
34
MD
35
MD
06
MD
12
MD
13
MD
36
MD
1
09
2
17
M
MD
18
T
MD
19
MD
16
3
40
M/T
41
42
4
53
5
54
M/T
MD
55
MD
56
MD
57
MD
6
04
25
26
58
59
92
74
7
60
M
MD
63
MD
64
T
MD
62
MD
8
70
71
_______
1)
As from SW 2
6–32
©
Siemens AG 1992 All Rights Reserved 6FC5197- AA50
SINUMERIK 840C (IA)