7 Drive Machine Data (SIMODRIVE Drive MD)
12.93
7.2.2 FDD MD (data description - SW 3)
Monitoring cycle
1002
Default value
Lower input limit
Upper input limit
Units
100 000
4 000
100 000
µ
s
Active on
Power On
The interrupt clock cycle is used for high-priority monitoring purposes. Note: The input value
for the clock cycle must be a whole multiple of 4 ms (parameterization error).
m x 4000
µ
s
m=1, 2, 3, ..., 25
Note:
The interrupt level must not be exceeded otherwise the drive will be tripped.
No. encoder marks motor measuring system
1005
Default value
Lower input limit
Upper input limit
Units
2 048
128
8 192
Incr/rev
Active on
Power On
Input of number of encoder increments per motor revolution of the motor measuring system.
Note:
The indirect measuring system must always be configured for FDD/MSD.
Frequency pulse-width modulation
1100
Default value
Lower input limit
Upper input limit
Units
3 200
2 000
8 000
Hz
Active on
Power On
The frequency of the sampling triangle in the PWM inverter is defined in this machine data.
The frequency values are set as an MMC function (see attached table).
Value table:
f
PBM
in Hz
T
PBM
in
µ
s
2000
500.0*
2064.5....
484.375
2133.3....
468.75
2206.8....
453.125
2285.7....
437.5*
2370.3....
421.875
2461.5....
406.25
2560
390.625
_______
*
A preselection with synchronous sampling period (TPWM) with respect to the controller cycles can be made
via the toggle button.
7–48
©
Siemens AG 1992 All Rights Reserved 6FC5197- AA50
SINUMERIK 840C (IA)