Siemens SINUMERIK 840C User Manual
Page 207

6 NC Machine Data (NC MD), NC Setting Data (NC SD)
09.95
6.2 General machine data (general data)
Language switchover
1)
250
Default value
Lower input limit
Upper input limit
Units
0
0
1
–
Active on
Power On
SINUMERIK 840C can display two languages at option.
The following entries are possible:
0 = Language 1
1 = Language 2
The following language combinations are available:
Language 1
Language 2
German
English
German
French
German
Italian
German
Spanish
English
French
English
Italian
English
Spanish
You can check which combination has been ordered and implemented via the ”Control info”
softkey.
M function ”C axis on”
260
Default value
Lower input limit
Upper input limit
Units
- 1
- 1
9 999
- 1
Active on
NC Stop
M function ”C axis off”
261
Default value
Lower input limit
Upper input limit
Units
- 1
- 1
9 999
-
Active on
NC Stop
Active:
when all channels of the mode group are in STOP status.
C axis operation is selected and deselected via M functions. The numbers of these M
functions can be allocated on a customer-specific basis.
_______
1)
Up to SW 1
6–22
©
Siemens AG 1992 All Rights Reserved 6FC5197- AA50
SINUMERIK 840C (IA)