Intel 253666-024US User Manual
Page 61

Vol. 2A 3-15
INSTRUCTION SET REFERENCE, A-M
letter mnemonic with the corresponding interrupt vector number and exception
name. See Chapter 5, “Interrupt and Exception Handling,” in the Intel® 64 and IA-32
Architectures Software Developer’s Manual, Volume 3A, for a detailed description of
the exceptions.
Application programmers should consult the documentation provided with their oper-
ating systems to determine the actions taken when exceptions occur.
Table 3-3. Intel 64 and IA-32 General Exceptions
Vector
No.
Name
Source
Protected
Mode
1
Real
Address
Mode
Virtual
8086
Mode
0
#DE—Divide Error
DIV and IDIV instructions.
Yes
Yes
Yes
1
#DB—Debug
Any code or data reference.
Yes
Yes
Yes
3
#BP—Breakpoint
INT 3 instruction.
Yes
Yes
Yes
4
#OF—Overflow
INTO instruction.
Yes
Yes
Yes
5
#BR—BOUND Range
Exceeded
BOUND instruction.
Yes
Yes
Yes
6
#UD—Invalid
Opcode (Undefined
Opcode)
UD2 instruction or reserved
opcode.
Yes
Yes
Yes
7
#NM—Device Not
Available (No Math
Coprocessor)
Floating-point or WAIT/FWAIT
instruction.
Yes
Yes
Yes
8
#DF—Double Fault
Any instruction that can
generate an exception, an
NMI, or an INTR.
Yes
Yes
Yes
10
#TS—Invalid TSS
Task switch or TSS access.
Yes
Reserved
Yes
11
#NP—Segment Not
Present
Loading segment registers or
accessing system segments.
Yes
Reserved
Yes
12
#SS—Stack
Segment Fault
Stack operations and SS
register loads.
Yes
Yes
Yes
13
#GP—General
Protection
2
Any memory reference and
other protection checks.
Yes
Yes
Yes
14
#PF—Page Fault
Any memory reference.
Yes
Reserved
Yes
16
#MF—Floating-Point
Error (Math Fault)
Floating-point or WAIT/FWAIT
instruction.
Yes
Yes
Yes
17
#AC—Alignment
Check
Any data reference in
memory.
Yes
Reserved
Yes