Sigma II Indexer User’s Manual
Settings According to Device Characteristics
5-10
Servo OFF Stop Mode Selection
The SGDH servo amplifier turns OFF under the following conditions:
• Servo ON input signal (/S-ON, CN1-40) is turned OFF.
• Servo alarm occurs.
• Power is turned OFF.
Specify the Stop Mode if any of these occur during operation.
Parameter
Signal
Setting
Pn819
Overtravel Stop Mode
Default Setting: 0
Parameter
Signal
Setting
Description
Pn819
Overtravel Stop Mode
0
Stops the servomotor the same way as turning the servo OFF (accord-
ing to Pn001.0). Servo is in baseblock after stopping.
1
Decelerates the servomotor immediately to a stop and puts the servo-
motor in servo lock.
2
Decelerates the servomotor to a stop at the preset deceleration and
puts the servomotor in servo lock.
Deceleration setting: Pn820 deceleration parameter
Parameter
Signal
Setting (x1000 ref. units/min/msec)
Default
Pn820
Deceleration
Range: 1 to 99999999
1000
Parameter
Signal
Setting
Pn001.0
Servo OFF or
Alarm Stop Mode
Default Setting: 0
- Tag Generator (30 pages)
- MP3300iec (82 pages)
- 1000 Hz High Frequency (18 pages)
- 1000 Series (7 pages)
- PS-A10LB (39 pages)
- iQpump Micro User Manual (300 pages)
- 1000 Series Drive Option - Digital Input (30 pages)
- 1000 Series Drive Option - CANopen (39 pages)
- 1000 Series Drive Option - Analog Monitor (27 pages)
- 1000 Series Drive Option - CANopen Technical Manual (37 pages)
- 1000 Series Drive Option - CC-Link (38 pages)
- 1000 Series Drive Option - CC-Link Technical Manual (36 pages)
- 1000 Series Drive Option - DeviceNet (37 pages)
- 1000 Series Drive Option - DeviceNet Technical Manual (81 pages)
- 1000 Series Drive Option - MECHATROLINK-II (32 pages)
- 1000 Series Drive Option - Digital Output (31 pages)
- 1000 Series Drive Option - MECHATROLINK-II Technical Manual (41 pages)
- 1000 Series Drive Option - Profibus-DP (35 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (36 pages)
- Z1000U HVAC MATRIX Drive Quick Start (378 pages)
- 1000 Series Operator Mounting Kit NEMA Type 4X (20 pages)
- 1000 Series Drive Option - Profibus-DP Technical Manual (44 pages)
- CopyUnitManager (38 pages)
- 1000 Series Option - JVOP-182 Remote LED (58 pages)
- 1000 Series Option - PG-X3 Line Driver (31 pages)
- SI-EN3 Technical Manual (68 pages)
- JVOP-181 (22 pages)
- JVOP-181 USB Copy Unit (2 pages)
- SI-EN3 (54 pages)
- SI-ET3 (49 pages)
- MECHATROLINK-III (35 pages)
- EtherNet/IP (50 pages)
- SI-EM3 (51 pages)
- 1000-Series Option PG-E3 Motor Encoder Feedback (33 pages)
- 1000-Series Option SI-EP3 PROFINET (56 pages)
- PROFINET (62 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (45 pages)
- SI-EP3 PROFINET Technical Manual (53 pages)
- A1000 Drive Option - BACnet MS/TP (48 pages)
- 120 Series I/O Modules (308 pages)
- A1000 12-Pulse (92 pages)
- A1000 Drive Software Technical Manual (16 pages)
- A1000 Quick Start (2 pages)
- JUNMA Series AC SERVOMOTOR (1 page)
- A1000 Option DI-101 120 Vac Digital Input Option (24 pages)