Yaskawa Sigma II Indexer User Manual
Page 178

Sigma II Indexer User’s Manual
Sigma II Indexer Status Display Table
9-7
9.2.2 Sigma II Indexer Error/Warning Status Display Table
Indexer
Status
Status
1
Code
Panel
2
Display
Detail
ALM
3
Output
/WARN
4
Display
Motor
Operation
Error
4
E41E
A.9F
Program Table Save Failure Error
ON
ON
No Change
E42E
A.9F
ZONE Table Save Failure Error
ON
ON
No Change
E43E
A.9F
JOG Speed Table Save Failure Error
ON
ON
No Change
E44E
A.9F
Program Table Checksum Error
ON
ON
No Change
E46E
A.9F
JOG Speed Table Checksum Error
ON
ON
No Change
E47E
A.9F
Serial Communication Receiving Buffer
Overflow Error
Buffer has a 100 command capacity. If over-
flow error occurs, then all commands stored
in the buffer are cleared.
ON
ON
No Change
E48E
A.9F
Serial Communication Parity Error
ON
ON
No Change
E49E
A.9F
Serial Communication Framing Error
ON
ON
No Change
E4AE
A.9F
Serial Communication Overrun Error
ON
ON
No Change
E4BE
A.9F
Moving Disable Error due to
P-OT
ON
ON
No Change
E4CE
A.9F
Moving Disable Error due to
N-OT
ON
ON
No Change
E4DE
A.9F
Moving Disable Error due to
P-LS
ON
ON
No Change
E4EE
A.9F
Moving Disable Error due to
N-LS
ON
ON
No Change
E4FE
A.9F
Position Reference “Out of Range” Error
ON
ON
No Change
E51E
A.9F
Position Non Reservation Error
A position must be reserved before a ST
command.
ON
ON
No Change
E52E
A.9F
Registration Distance Non Reservation
Error
A registration distance (RDST) must be
reserved before a RS command.
ON
ON
No Change
E53E
A.9F
Move Reference Duplication Error
New positioning move command sent
before previous commanded positioning
move complete. Previous commanded posi-
tioning move must be complete before com-
manding a new positioning move.
ON
ON
No Change