Yaskawa Sigma II Indexer User Manual
Page 117

Sigma II Indexer User’s Manual
Zone Table Set-up
5-62
Setting Range: -99999999 ~ +99999999 reference units
Setting at Shipping: ZONE N = ZONE P = 0
Note: 1. Status of Z0~Z4 fixed for each zone.
2. Zone signals function only when the programmable outputs (/POUT0-/POUT4) are defined as a
zone output
o Z. Example: POUT = ZAZZN. Status of programmable outputs /POUT1, /POUT2,
and /POUT4 dependent upon zone table.
5.9.1 Zone Signal Conditions
1. ZONEN
dZONEP
Condition for Z0~Z4 true when ZONEN
d Current Position d ZONEP
2. ZONEID with lower number is used when the current position falls within multiple
zones (overlapping zones).
3. Z0~Z4 Non-Active when there is no ZONEN
d Current Position d ZONEP.
4. ZONEN > ZONEP:
Condition for Z0~Z4 true when Current Position
t ZONEN or Current Position
d ZONEP
For example: When position 0 is within a zone of a rotary application
Therefore, Z3 and Z2 active when current position is within ZONEID12.
5. ZONEN = ZONEP = 0:
Zone is not reserved.
- Tag Generator (30 pages)
- MP3300iec (82 pages)
- 1000 Hz High Frequency (18 pages)
- 1000 Series (7 pages)
- PS-A10LB (39 pages)
- iQpump Micro User Manual (300 pages)
- 1000 Series Drive Option - Digital Input (30 pages)
- 1000 Series Drive Option - CANopen (39 pages)
- 1000 Series Drive Option - Analog Monitor (27 pages)
- 1000 Series Drive Option - CANopen Technical Manual (37 pages)
- 1000 Series Drive Option - CC-Link (38 pages)
- 1000 Series Drive Option - CC-Link Technical Manual (36 pages)
- 1000 Series Drive Option - DeviceNet (37 pages)
- 1000 Series Drive Option - DeviceNet Technical Manual (81 pages)
- 1000 Series Drive Option - MECHATROLINK-II (32 pages)
- 1000 Series Drive Option - Digital Output (31 pages)
- 1000 Series Drive Option - MECHATROLINK-II Technical Manual (41 pages)
- 1000 Series Drive Option - Profibus-DP (35 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (36 pages)
- Z1000U HVAC MATRIX Drive Quick Start (378 pages)
- 1000 Series Operator Mounting Kit NEMA Type 4X (20 pages)
- 1000 Series Drive Option - Profibus-DP Technical Manual (44 pages)
- CopyUnitManager (38 pages)
- 1000 Series Option - JVOP-182 Remote LED (58 pages)
- 1000 Series Option - PG-X3 Line Driver (31 pages)
- SI-EN3 Technical Manual (68 pages)
- JVOP-181 (22 pages)
- JVOP-181 USB Copy Unit (2 pages)
- SI-EN3 (54 pages)
- SI-ET3 (49 pages)
- MECHATROLINK-III (35 pages)
- EtherNet/IP (50 pages)
- SI-EM3 (51 pages)
- 1000-Series Option PG-E3 Motor Encoder Feedback (33 pages)
- 1000-Series Option SI-EP3 PROFINET (56 pages)
- PROFINET (62 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (45 pages)
- SI-EP3 PROFINET Technical Manual (53 pages)
- A1000 Drive Option - BACnet MS/TP (48 pages)
- 120 Series I/O Modules (308 pages)
- A1000 12-Pulse (92 pages)
- A1000 Drive Software Technical Manual (16 pages)
- A1000 Quick Start (2 pages)
- JUNMA Series AC SERVOMOTOR (1 page)
- A1000 Option DI-101 120 Vac Digital Input Option (24 pages)