B.1 monitor modes – Yaskawa Sigma II Indexer User Manual
Page 199

Sigma II Indexer User’s Manual
Monitor Modes
Appendix B-2
B.1 Monitor Modes
The following list shows monitor modes available via the CN7 port when using a digital operator
Table B.1: Monitor Modes
Digital
Operator
(CN7)
Content of Display
Unit
Remarks
Equivalent Serial
Command (CN6)
Un000
Actual Motor Speed
rpm
—
NFB or MON3
Un001
N/A
—
—
N/A
Un002
Internal Torque Reference
%
Value for
rated torque
TREF or MON5
Un003
Rotational Angle 1
Pulse
Number of
Pulses from
Origin
None
Un004
Electrical Angle 2
Degree
Angle from
Origin (elec-
trical)
None
Un005
SGDH Input Signal Monitor
—
—
IN1
Un006
SGDH Output Signal Monitor
—
—
OUT1
Un007
Input Reference Pulse Speed
rpm
—
NREF or MON4
Un008
Position Error
reference units
—
PER or MON2
Un009
Accumulated Load Rate
%
(1)
TRMS
Un00A
Regenerative Load Rate
%
(2)
RGRMS
Un00B
Power Consumed by DB Resistor
%
(3)
DBRMS
Un00C
SGDH Position Reference Counter
—
Display in
Hexadecimal
None
Un00D
PG Counter Feedback Pulse Counter
—
Display in
Hexadecimal
None
Un800
Last Error
—
—
ERR
Un801
NS600 Input Signal Monitor
—
—
IN2
Un802
NS600 Output Signal Monitor
—
—
OUT2
Un803
Status Flag Monitor
—
—
STS or MON6
Un804
Current Issue Position Monitor
reference units
—
PUN or MON1
Un805
Current Motor Position Monitor
reference units
—
PFB or MON7
Un806
Target Position Monitor
reference units
—
POS or MON8
Un807
Target Distance Monitor
reference units
—
DST or MON9
Un808
Registration Target Position Monitor
reference units
—
RPOS or MON10
Un809
Registration Target Distance Monitor
reference units
—
RDST or MON11