7. Enter your e-mail address in the field Operator e-mail. Sunny Portal will send the access data to this e-mail

address.

8. Select the button [Save].

9. Select Sunny Central > Info.

10. Select [Register] in the field Last Sunny Portal registration. The Sunny Portal password will be sent to the e-

mail address you have entered.

6.2.2.2

Adjusting the PV System Identifier for Sunny Portal

Sunny Portal identifies the inverter via the PV system identifier. In the following cases, you will need to adjust the PV
system identifier of the inverter:

• Data of the PV power plant has already been sent to Sunny Portal via another communication unit.

• The set PV system identifier of the communication unit has been reset.

• The communication unit has been replaced.

Procedure:

1. Log into Sunny Portal (www.SunnyPortal.com).

2. Select Configuration > PV system properties.

3. Copy the PV system identifier to the clipboard.

4. Log into the user interface (see Section 9.4.1, page 81).

5. Select Sunny Central > Settings > Data transmission.

6. Delete the content of the PV system identifier field.

7. Paste the PV system identifier from the clipboard into the PV system identifier field.

8. Select the button [Save].

6.2.2.3

Deleting the Sunny Portal Buffer

You can delete the data on the internal ring buffer.

Procedure:

1. Log into the user interface as an installer (see Section 9.4.1, page 81).

2. Select Sunny Central > Info.

3. Select the button [Delete] in the field Sunny Portal Buffer Load.

6.3

Saving Operating Data

6.3.1

Reducing Storage Capacity by Averaging

The communication unit can average the data over a defined time period. This helps to compress the data of the
connected devices so that it occupies less memory space in the communication unit.

Procedure:

1. Log into the user interface (see Section 9.4.1, page 81).

2. Select Sunny Central > Recording.

3. In the field Averaging over, select the time period over which the communication unit is to calculate the

average.

4. Select the button [Save].

6 Operation

SMA Solar Technology AG

User Manual

SCCPXT-BA-E4-en-54