Name

Description

Value/range

Explanation

Default
value

Q-VLockInW** Voltage value from

which the Q(V) charac-
teristic curve is activated,
in % relative to the nomi-
nal voltage

0 % … 100 %

0 %

Q-VLockOutW
**

Voltage value from
which the Q(V) charac-
teristic curve is deacti-
vated, in % based on the
nominal voltage

0 % … 100 %

0 %

Q-VLockInTm
**

Waiting time for activa-
tion of the Q(V) charac-
teristic curve

0 s to 100 s

2 s

Q-VLockOutTm
**

Waiting time for deacti-
vation of the Q(V) char-
acteristic curve

0 s to 100 s

2 s

Q-
VArGraNomPo
s**

Reactive power gradient
at a positive change of
nominal voltage

0%/V to 40.06%/V

Sunny Central 500CP XT

0%/V

0%/V to 31.47%/V

Sunny Central 630CP XT

0%/V to 27.82%/V

Sunny Central 720CP XT

0%/V to 26.35%/V

Sunny Central 760CP XT

0%/V to 25.04%/V

Sunny Central 800CP XT

0%/V to 23.56%/V

Sunny Central 850CP XT

0%/V to 22.25%/V

Sunny Central 900CP XT

Q-
VArGraNomN
eg**

Reactive power gradient
at a negative change of
nominal voltage

0%/V to 40.06%/V

Sunny Central 500CP XT

0%/V

0%/V to 31.47%/V

Sunny Central 630CP XT

0%/V to 27.82%/V

Sunny Central 720CP XT

0%/V to 26.35%/V

Sunny Central 760CP XT

0%/V to 25.04%/V

Sunny Central 800CP XT

0%/V to 23.56%/V

Sunny Central 850CP XT

0%/V to 22.25%/V

Sunny Central 900CP XT

PF-
PFSubValRun

Substitute value cos φ in
normal feed-in operation
during communication
disturbance

The lower limit is defined
by the parameter PFAb-
sMin
.

0.5 … 1

1

11 Operating Data and Parameters

SMA Solar Technology AG

User Manual

133