2 parameters and values for the file custom.xml, Parameters and values for the file custom.xml – SMA SC 500CP XT User Manual
Page 151
Elements of the XML file
Explanation
Required element of the XML file. You must enter
the name and the version for your settings between
the version tags. This information is displayed in the
header of the user interface.
Here, you can set the parameters and their corre-
sponding values (see Section 12.3.2, page 151).
Here, you can set the time period in ms which must
expire before the communication unit will shut
down after the UPS of the inverter has signaled a
failure of the supply voltage to the communication
unit. The value must be greater than or equal to
2,500. This setting is immediately adopted once
the file is uploaded.
Example: XML file for setting the Czech language on the user interface
12.3.2 Parameters and Values for the File custom.xml
Parameter
Explanation
Values
Default val-
ues
NetworkSettings_DhcpUsage1
Activates DHCP for LAN2. With the
True value, all other settings of the IP
addresses for LAN2 will be ignored.
True
False
False
NetworkSettings_DnsIpAddr1
Sets the first IPv4 address of the DNS
server for LAN2
‒
‒
0.0.0.0
A valid IPv4
address
12 Appendix
SMA Solar Technology AG
User Manual
151
SCCPXT-BA-E4-en-54
- SC 630CP XT SC 720CP XT SC 760CP XT SC 800CP XT SC 850CP XT SC 900CP XT SC 500CP XT Maintenance Manual SC 630CP XT Maintenance Manual SC 720CP XT Maintenance Manual SC 760CP XT Maintenance Manual SC 800CP XT Maintenance Manual SC 850CP XT Maintenance Manual SC 900CP XT Maintenance Manual SC 1000CP XT SC 1000CP XT Maintenance Manual