beautypg.com

HEIDENHAIN TNC 640 (34059x-05) Cycle programming User Manual

Page 572

background image

Touch Probe Cycles: Special Functions

17.6

CALIBRATE TS (Cycle 460, DIN/ISO: G460)

17

572

TNC 640 | User's Manual Cycle Programming | 1/2015

Exact calibration sphere radius Q407: Enter the
exact radius of the calibration sphere used. Input
range 0.0001 to 99.9999
Set-up clearance Q320 (incremental): Additional
distance between measuring point and ball tip.
Q320 is added to SET_UP in the touch probe table.
Input range 0 to 99999.9999
Traversing to clearance height Q301: Definition
of how the touch probe is to move between the
measuring points:

0

: Move at measuring height between measuring

points

1

: Move at clearance height between measuring

points
Number of probe points in the plane (4/3) Q423:
Number of measuring points on the diameter. Input
range 0 to 8
Reference angle Q380 (absolute): Reference
angle (basic rotation) for measuring the measuring
points in the active workpiece coordinate system.
Defining a reference angle can considerably enlarge
the measuring range of an axis. Input range 0 to
360.0000
Calibrate length (0/1) Q433: Define whether the
TNC should also calibrate the touch probe length
after radius calibration:

0

: Do not calibrate touch probe length

1

: Calibrate touch probe length

Datum for length Q434 (absolute): Coordinate of
the calibration sphere center. The definition is only
required if length calibration is to be carried out.
Input range -99999.9999 to 99999.9999

NC blocks

5 TCH PROBE 460 CALIBRATE TS

Q407=12.5

;SPHERE RADIUS

Q320=0

;SET-UP CLEARANCE

Q301=1

;MOVE TO CLEARANCE

Q423=4

;NO. OF PROBE POINTS

Q380=+0

;REFERENCE ANGLE

Q433=0

;CALIBRATE LENGTH

Q434=-2.5

;DATUM