beautypg.com

Cycle parameters – HEIDENHAIN TNC 640 (34059x-05) Cycle programming User Manual

Page 486

background image

Touch Probe Cycles: Automatic Datum Setting

15.5 DATUM FROM OUTSIDE OF RECTANGLE (Cycle 411, DIN/ISO: G411)

15

486

TNC 640 | User's Manual Cycle Programming | 1/2015

Cycle parameters

Center in 1st axis Q321 (absolute): Center of the
stud in the reference axis of the working plane.
Input range -99999.9999 to 99999.9999
Center in 2nd axis Q322 (absolute): Center of the
stud in the minor axis of the working plane. Input
range -99999.9999 to 99999.9999
1st side length Q323 (incremental): Stud length,
parallel to the reference axis of the working plane
Input range 0 to 99999.9999
2nd side length Q324 (incremental): Stud length,
parallel to the minor axis of the working plane. Input
range 0 to 99999.9999
Measuring height in the touch probe axis Q261
(absolute): Coordinate of the ball tip center (=
touch point) in the touch probe axis in which
the measurement is to be made. Input range
-99999.9999 to 99999.9999
Set-up clearance Q320 (incremental): Additional
distance between measuring point and ball tip.
Q320 is added to

SET_UP (touch probe table). Input

range 0 to 99999.9999
Clearance height Q260 (absolute): Coordinate in
the touch probe axis at which no collision between
touch probe and workpiece (fixtures) can occur.
Input range -99999.9999 to 99999.9999
Traversing to clearance height Q301: definition
of how the touch probe is to move between the
measuring points:

0

: Move at measuring height between measuring

points

1

: Move at clearance height between measuring

points
Datum number in table Q305: Enter the number in
the datum/preset table in which the TNC is to save
the coordinates of the stud center. If Q303=1: If
you enter Q305=0, the TNC automatically sets the
display so that the new datum is on the stud center.
If Q303=0: If you enter Q305=0, the TNC writes to
line 0 of the datum table. Input range 0 to 99999

NC blocks

5 TCH PROBE 411 DATUM OUTS.

RECTAN.
Q321=+50

;CENTER IN 1ST AXIS

Q322=+50

;CENTER IN 2ND AXIS

Q323=60

;FIRST SIDE LENGTH

Q324=20

;2ND SIDE LENGTH

Q261=-5

;MEASURING HEIGHT

Q320=0

;SET-UP CLEARANCE

Q260=+20

;CLEARANCE HEIGHT

Q301=0

;MOVE TO CLEARANCE

Q305=0

;NO. IN TABLE

Q331=+0

;DATUM