beautypg.com

Configuring the datum table, To exit a datum table, Status displays – HEIDENHAIN TNC 640 (34059x-05) Cycle programming User Manual

Page 260

background image

Cycles: Coordinate Transformations

10.3

DATUM SHIFT with datum tables (Cycle 7, DIN/ISO: G53)

10

260

TNC 640 | User's Manual Cycle Programming | 1/2015

Configuring the datum table

If you do not wish to define a datum for an active axis, press
the

DEL key. Then the TNC clears the numerical value from the

corresponding input field.

You can change the properties of tables. Enter the
code number 555343 in the MOD menu. The TNC
then offers the EDIT FORMAT soft key if a table is
selected. When you press this soft key, the TNC
opens a pop-up window where the properties are
shown for each column of the selected table. Any
changes made only affect the open table.

To exit a datum table

Select a different type of file in file management and choose the
desired file.

After you have changed a value in a datum table, you
must save the change with the

ENT key. Otherwise

the change may not be included during program run.

Status displays

In the additional status display, the TNC shows the values of the
active datum shift.