beautypg.com

4 datum setting (cycle 247, din/iso: g247), Effect, Please note before programming – HEIDENHAIN TNC 640 (34059x-05) Cycle programming User Manual

Page 261: Cycle parameters, Status displays, Datum setting (cycle 247, din/iso: g247)

background image

DATUM SETTING (Cycle 247, DIN/ISO: G247)

10.4

10

TNC 640 | User's Manual Cycle Programming | 1/2015

261

10.4

DATUM SETTING (Cycle 247, DIN/
ISO: G247)

Effect

With the DATUM SETTING cycle you can activate as the new
datum a preset defined in a preset table.

After a DATUM SETTING cycle definition, all of the coordinate
inputs and datum shifts (absolute and incremental) are referenced
to the new preset.

Status display

In the status display the TNC shows the active preset number
behind the datum symbol.

Please note before programming:

When activating a datum from the preset table,
the TNC resets the datum shift, mirroring, rotation,
scaling factor and axis-specific scaling factor.

If you activate preset number 0 (line 0), then you
activate the datum that you last set in the

Manual

Operation or El. Handwheel operating mode.
Cycle 247 is not functional in

Test Run mode.

Cycle parameters

Number for datum?: Enter the number of the
datum to be activated from the preset table. Input
range: 0 to 65535

NC blocks

13 CYCL DEF 247 DATUM SETTING

Q339=4

;DATUM NUMBER

Status displays

In the additional status display (

POS. DISP. STATUS) the TNC shows

the active preset number behind the

datum dialog.