Cycle parameters

Center in 1st axis Q273 (absolute): Center of the
hole in the reference axis of the working plane.
Input range -99999.9999 to 99999.9999
Center in 2nd axis Q274 (absolute value): Center
of the hole in the minor axis of the working plane.
Input range -99999.9999 to 99999.9999
Nominal diameter Q262: Enter the diameter of the
hole. Input range 0 to 99999.9999
Starting angle Q325 (absolute): Angle between the
reference axis of the working plane and the first
touch point. Input range -360.000 to 360.000
Stepping angle Q247 (incremental): Angle between
two measuring points. The algebraic sign of the
stepping angle determines the direction of rotation
(negative = clockwise) in which the touch probe
moves to the next measuring point. If you wish to
probe a circular arc instead of a complete circle,
then program the stepping angle to be less than
90°. Input range -120.000 to 120.000
Measuring height in the touch probe axis Q261
(absolute): Coordinate of the ball tip center (=
touch point) in the touch probe axis in which
the measurement is to be made. Input range
-99999.9999 to 99999.9999
Set-up clearance Q320 (incremental): Additional
distance between measuring point and ball tip.
Q320 is added to

SET_UP (touch probe table). Input

range 0 to 99999.9999
Clearance height Q260 (absolute): Coordinate in
the touch probe axis at which no collision between
touch probe and workpiece (fixtures) can occur.
Input range -99999.9999 to 99999.9999
Traversing to clearance height Q301: definition
of how the touch probe is to move between the
measuring points:

0

: Move at measuring height between measuring

points

1

: Move at clearance height between measuring

points
Maximum limit of size for hole Q275: Maximum
permissible diameter for the hole (circular pocket).
Input range 0 to 99999.9999
Minimum limit of size for hole Q276: Minimum
permissible diameter for the hole (circular pocket).
Input range 0 to 99999.9999
Tolerance for center 1st axis Q279: Permissible
position deviation in the reference axis of the
working plane. Input range 0 to 99999.9999
Tolerance for center 2nd axis Q280: Permissible
position deviation in the minor axis of the working
plane. Input range 0 to 99999.9999

NC blocks

5 TCH PROBE 421 MEASURE HOLE

Q273=+50

;CENTER IN 1ST AXIS

Q274=+50

;CENTER IN 2ND AXIS

Q262=75

;NOMINAL DIAMETER

Q325=+0

;STARTING ANGLE

Q247=+60

;STEPPING ANGLE

Q261=-5

;MEASURING HEIGHT

Q320=0

;SET-UP CLEARANCE

Q260=+20

;CLEARANCE HEIGHT

Q301=1

;MOVE TO CLEARANCE

Q275=75.12

;MAXIMUM DIMENSION

Q276=74.95

;MINIMUM DIMENSION

Q279=0.1

;TOLERANCE 1ST

CENTER

Q280=0.1

;TOLERANCE 2ND

CENTER

Q281=1

;MEASURING LOG

Q309=0

;PGM STOP IF ERROR

Q330=0

;TOOL

Q423=4

;NO. OF PROBE POINTS

Q365=1

;TYPE OF TRAVERSE