beautypg.com

Cycle parameters – HEIDENHAIN TNC 640 (34059x-05) Cycle programming User Manual

Page 483

background image

DATUM FROM INSIDE OF RECTANGLE (Cycle 410, DIN/ISO: G410) 15.4

15

TNC 640 | User's Manual Cycle Programming | 1/2015

483

Cycle parameters

Center in 1st axis Q321 (absolute): Center of the
pocket in the reference axis of the working plane.
Input range -99999.9999 to 99999.9999
Center in 2nd axis Q322 (absolute): Center of the
pocket in the minor axis of the working plane. Input
range -99999.9999 to 99999.9999
1st side length Q323 (incremental): Pocket length,
parallel to the reference axis of the working plane.
Input range 0 to 99999.9999
2nd side length Q324 (incremental): Pocket length,
parallel to the minor axis of the working plane. Input
range 0 to 99999.9999
Measuring height in the touch probe axis Q261
(absolute): Coordinate of the ball tip center (=
touch point) in the touch probe axis in which
the measurement is to be made. Input range
-99999.9999 to 99999.9999
Set-up clearance Q320 (incremental): Additional
distance between measuring point and ball tip.
Q320 is added to

SET_UP (touch probe table). Input

range 0 to 99999.9999
Clearance height Q260 (absolute): Coordinate in
the touch probe axis at which no collision between
touch probe and workpiece (fixtures) can occur.
Input range -99999.9999 to 99999.9999
Traversing to clearance height Q301: definition
of how the touch probe is to move between the
measuring points:

0

: Move at measuring height between measuring

points

1

: Move at clearance height between measuring

points
Datum number in table Q305: Enter the number in
the datum/preset table in which the TNC is to save
the coordinates of the pocket center. If Q303=1: If
you enter Q305=0, the TNC automatically sets the
display so that the new datum is at the center of the
pocket. If Q303=0: If you enter Q305=0, the TNC
writes to line 0 of the datum table. Input range 0 to
99999
New datum for reference axis Q331 (absolute):
Coordinate in the reference axis at which the TNC
should set the pocket center. Default setting = 0.
Input range -99999.9999 to 99999.9999
New datum for minor axis Q332 (absolute):
Coordinate in the minor axis at which the TNC
should set the pocket center. Default setting = 0
input range -99999.9999 to 99999.9999

NC blocks

5 TCH PROBE 410 DATUM INSIDE

RECTAN.
Q321=+50

;CENTER IN 1ST AXIS

Q322=+50

;CENTER IN 2ND AXIS

Q323=60

;FIRST SIDE LENGTH

Q324=20

;2ND SIDE LENGTH

Q261=-5

;MEASURING HEIGHT

Q320=0

;SET-UP CLEARANCE

Q260=+20

;CLEARANCE HEIGHT

Q301=0

;MOVE TO CLEARANCE

Q305=10

;NO. IN TABLE

Q331=+0

;DATUM

Q332=+0

;DATUM

Q303=+1

;MEAS. VALUE

TRANSFER

Q381=1

;PROBE IN TS AXIS

Q382=+85

;1ST CO. FOR TS AXIS

Q383=+50

;2ND CO. FOR TS AXIS

Q384=+0

;3RD CO. FOR TS AXIS

Q333=+1

;DATUM