Touch Probe Cycles: Automatic Measurement of Workpiece Misalignment

14.3 BASIC ROTATION over two holes (Cycle 401, DIN/ISO: G401)

14

454

TNC 640 | User's Manual Cycle Programming | 1/2015

Cycle parameters

1st hole: Center in 1st axis Q268 (absolute):
Center of the first hole in the reference axis of
the working plane. Input range -99999.9999 to
99999.9999
1st hole: Center in 2nd axis Q269 (absolute):
Center of the first hole in the minor axis of
the working plane. Input range -99999.9999 to
99999.9999
2nd hole: Center in 1st axis Q270 (absolute):
Center of the second hole in the reference axis
of the working plane. Input range -99999.9999 to
99999.9999
2nd hole: Center in 2nd axis Q271 (absolute):
Center of the second hole in the minor axis of
the working plane. Input range -99999.9999 to
99999.9999
Measuring height in the touch probe axis Q261
(absolute): Coordinate of the ball tip center (=
touch point) in the touch probe axis in which
the measurement is to be made. Input range
-99999.9999 to 99999.9999
Clearance height Q260 (absolute): Coordinate in
the touch probe axis at which no collision between
touch probe and workpiece (fixtures) can occur.
Input range -99999.9999 to 99999.9999
Preset value for rotation angle Q307 (absolute):
If the misalignment is to be measured against a
straight line other than the reference axis, enter
the angle of this reference line. The TNC will
then calculate the difference between the value
measured and the angle of the reference line for the
basic rotation. Input range -360.000 to 360.000

Preset number in table Q305: Enter the preset
number in the table in which the TNC is to save the
determined basic rotation. If you enter Q305=0,
the TNC automatically places the determined
basic rotation in the ROT menu of the Manual
Operation mode. The parameter has no effect
if the misalignment is to be compensated by a
rotation of the rotary table (

Q402=1). In this case

the misalignment is not saved as an angular value.
Input range 0 to 99999

NC blocks

5 TCH PROBE 401 ROT OF 2 HOLES

Q268=-37

;1ST CENTER IN 1ST

AXIS

Q269=+12

;1ST CENTER 2ND AXIS

Q270=+75

;2ND CENTER 1ST AXIS

Q271=+20

;2ND CENTER 2ND AXIS

Q261=-5

;MEASURING HEIGHT

Q260=+20

;CLEARANCE HEIGHT

Q307=0

;PRESET ROT. ANGLE

Q305=0

;NO. IN TABLE

Q402=0

;COMPENSATION

Q337=0

;ZERO RESET