beautypg.com

Connect uim-san-fcip network cables dell 1950, Connect uim-san-fcip network cables, Dell 1950 – Grass Valley UIM v.2.1.1 User Manual

Page 96

background image

96

UIM Instruction Manual

February 5, 2008

Chapter 5 UIM-SAN-FCIP Installation: Grass Valley Open SAN System

Connect UIM-SAN-FCIP network cables
Dell 1950

Connect the network cables as shown. Be sure to consult your Ethernet and Fibre
Channel switch fabric designs as you make connections. Refer to

“Onsite planning”

on page 82

.

UIM

Fibre Channel IP

Streaming Port

To Fibre Channel

Switch (IP)

Fibre Channel
SCSI Connection
To Fibre Channel
Switch (SCSI)

A

B

Control Team

Ports A/B

(Control LAN)

NOTE:
1. Ensure that the redundant and primary ports are
connected to different switches. If redundant connections
are not used, unused ports are ignored.
2. Verify that the Ethernet switches support Spanning Tree
Protocol (STP), and that the protocol is configured as
described in

“Redundant Ethernet network requirements”

on page 17

.

!

CAUTION: Do not connect IP port on the
UIM-SAN-FCIP to the Fibre Channel SCSI
fabric. The IP driver will cause Open SAN
record and playout to fail. Do not mix IP and
SCSI fabrics on the same Fibre Channel switch.

This manual is related to the following products: