Connect uim-san-fcip network cables dell 1950, Connect uim-san-fcip network cables, Dell 1950 – Grass Valley UIM v.2.1.1 User Manual
Page 96

96
UIM Instruction Manual
February 5, 2008
Chapter 5 UIM-SAN-FCIP Installation: Grass Valley Open SAN System
Connect UIM-SAN-FCIP network cables
Dell 1950
Connect the network cables as shown. Be sure to consult your Ethernet and Fibre
Channel switch fabric designs as you make connections. Refer to
UIM
Fibre Channel IP
Streaming Port
To Fibre Channel
Switch (IP)
Fibre Channel
SCSI Connection
To Fibre Channel
Switch (SCSI)
A
B
Control Team
Ports A/B
(Control LAN)
NOTE:
1. Ensure that the redundant and primary ports are
connected to different switches. If redundant connections
are not used, unused ports are ignored.
2. Verify that the Ethernet switches support Spanning Tree
Protocol (STP), and that the protocol is configured as
described in
“Redundant Ethernet network requirements”
.
!
CAUTION: Do not connect IP port on the
UIM-SAN-FCIP to the Fibre Channel SCSI
fabric. The IP driver will cause Open SAN
record and playout to fail. Do not mix IP and