Connect uim-san-geip network cables dell 2650, Connect uim-san-geip network cables, Dell 2650 – Grass Valley UIM v.2.1.1 User Manual
Page 64: Connect uim-san-geip network cables dell

64
UIM Instruction Manual
February 5, 2008
Chapter 4 UIM-SAN-GEIP Installation: Grass Valley Open SAN System
Connect UIM-SAN-GEIP network cables
Dell 2650
Connect the network cables for each UIM-SAN-GEIP as shown. Be sure to consult
your Ethernet and Fibre Channel switch fabric designs as you make connections.
Refer to
.
Fibre Channel
Connection
To Fibre Channel
Switch (SCSI)
SCSI UIM
Integrated
1000BT
Ports
(Not Used)
Control Team
Intel Ports A/B
(Control LAN)
Streaming Team
Intel Ports C/D
(Streaming LAN)
NOTE:
1. Ensure that the redundant and primary ports are connected to different
switches. If redundant connections are not used, unused ports are
ignored.
2. Verify that the Ethernet switches support Spanning Tree Protocol
(STP), and that the protocol is configured as described in
Ethernet network requirements” on page 17
.
!
CAUTION: Do not connect the
UIM-SAN-GEIP to the Fibre Channel switch
fabric until after you have performed
the Fibre Channel adapter IP driver” on
page 53
. The IP driver will cause Open SAN
record and playout to fail.