beautypg.com

Grass Valley UIM v.2.1.1 User Manual

Page 90

background image

90

UIM Instruction Manual

February 5, 2008

Chapter 5 UIM-SAN-FCIP Installation: Grass Valley Open SAN System

To modify the FSM master hosts file:

1. On the FSM, make a copy of the master hosts and name it hosts.bak. The hosts file

is located at c:\winnt\system32\drivers\etc\hosts.

This copy can be used to recover the original file if there is a problem.

2. Open the hosts file at c:\winnt\system32\drivers\etc\hosts using Notepad or some

other text editor.

3. Use the following steps to type the entry for the UIM-SAN-FCIP network interface

connected to the control LAN.

a. On a single line, enter the IP address for the network interface connected to the

control LAN.

b. Insert a few spaces, then type the UIM-SAN-FCIP host name followed by the

_UIM1 suffix.

For example:

192.168.100.157

SAN1_UIM1

c. Insert a few more spaces, then type all Profile platform host names assigned to

this UIM-SAN-FCIP. Use the Profile host name followed by the _UIMFC
suffix.

SAN1_XP1

SAN1_XP2

SAN1_FSM2

SAN1_FSM1

Fibre Channel Switch Fabric (SCSI)

SAN1_UIM1

10/100BT Ethernet LAN (Control) x.x.100.x

Shared Storage

SAN1

SAN2_XP1

SAN2_XP2

SAN2_FSM2

SAN2_FSM1

Fibre Channel Switch Fabric (SCSI)

SAN2_UIM1

Shared Storage

SAN2

)

T Ethernet LAN x.x.100.x (C

Fibre

el

Chann

0.x

x.x.230

Profile XP
Platform
(Standalone)

FC IP Network (Streaming) x.x.230.x

Notes:
[1] Optional redundant Ethernet
fabrics, and Fibre Channel switch
fabrics are not shown.