Installing uim system software, Part 1: install uim system software version 2.x.x – Grass Valley UIM v.2.1.1 User Manual
Page 21

February 5, 2008
UIM Instruction Manual
21
Installing UIM System Software
Installing UIM System Software
System Software 2.x.x is installed on all UIMs at the factory. In normal operation, you
should not need to install UIM System Software 2.x.x. If your UIM is operating with
an earlier version of system software, you should update to the current version.
NOTE: If you are upgrading your UIM from a System Software version earlier
than 1.0.0.3, please contact your Grass Valley representative for instructions
specific to that upgrade.
This software installation procedure includes:
•
“Part 1: Install UIM system software version 2.x.x”
•
“Part 2: Create a system disk image file”
NOTE: Make sure you have your Microsoft Windows CD on hand. If not already
installed, the UIM system software upgrade prompts you to install Management
and Monitoring components, which are on the Microsoft Windows CD.
Part 1: Install UIM system software version 2.x.x
To install UIM system software version 2.x.x:
1. Power on the UIM and log on to the Windows operating system as administrator
(default password: triton).
2. Remove the previous version of UIM software using
Control Panel | Add/Remove
Program
s, then restart the system.
3. Insert the UIM System Software CD-ROM in the CD-ROM reader or connect to a
network drive containing the downloaded software.
The software installation will start automatically. (You may choose to run the
setup.exe program by choosing
Start | Run
and specifying the appropriate drive.).
4. Click
Next
in the Welcome screen, and accept the terms of the license agreement.
5. On the UIM Configuration page, select
IP Installation
or
SCSI (Open SAN)
Installation
option, then click
Next
and follow onscreen instructions.
Refer to
“Install UIM-SAN-GEIP System Software for Open SAN” on page 54
for
instructions on the remaining screens for the Open SAN installation option.