beautypg.com

Connect uim-san-geip network cables dell 1950, Connect uim-san-geip network cables, Dell 1950 – Grass Valley UIM v.2.1.1 User Manual

Page 66

background image

66

UIM Instruction Manual

February 5, 2008

Chapter 4 UIM-SAN-GEIP Installation: Grass Valley Open SAN System

Connect UIM-SAN-GEIP network cables
Dell 1950

Connect the network cables for each UIM-SAN-GEIP as shown. Be sure to consult
your Ethernet and Fibre Channel switch fabric designs as you make connections.
Refer to

“Onsite planning” on page 50

.

NOTE:
1. Ensure that the redundant and primary ports are connected to different
switches. If redundant connections are not used, unused ports are
ignored.
2. Verify that the Ethernet switches support Spanning Tree Protocol
(STP), and that the protocol is configured as described in

“Redundant

Ethernet network requirements” on page 17

.

!

CAUTION: Do not connect the
UIM-SAN-GEIP to the Fibre Channel switch
fabric until after you have performed

“Uninstall

the Fibre Channel adapter IP driver” on
page 53

. The IP driver will cause Open SAN

record and playout to fail.

Fibre Channel
Connection
To Fibre Channel
Switch (SCSI)

D

C

Streaming Teaming

Ports C/D

(Streaming LAN)

A

B

Control Team

Ports A/B

(Control LAN)

This manual is related to the following products: