Connect uim-san-geip network cables dell 1950, Connect uim-san-geip network cables, Dell 1950 – Grass Valley UIM v.2.1.1 User Manual
Page 66

66
UIM Instruction Manual
February 5, 2008
Chapter 4 UIM-SAN-GEIP Installation: Grass Valley Open SAN System
Connect UIM-SAN-GEIP network cables
Dell 1950
Connect the network cables for each UIM-SAN-GEIP as shown. Be sure to consult
your Ethernet and Fibre Channel switch fabric designs as you make connections.
Refer to
.
NOTE:
1. Ensure that the redundant and primary ports are connected to different
switches. If redundant connections are not used, unused ports are
ignored.
2. Verify that the Ethernet switches support Spanning Tree Protocol
(STP), and that the protocol is configured as described in
Ethernet network requirements” on page 17
.
!
CAUTION: Do not connect the
UIM-SAN-GEIP to the Fibre Channel switch
fabric until after you have performed
the Fibre Channel adapter IP driver” on
page 53
. The IP driver will cause Open SAN
record and playout to fail.
Fibre Channel
Connection
To Fibre Channel
Switch (SCSI)
D
C
Streaming Teaming
Ports C/D
(Streaming LAN)
A
B
Control Team
Ports A/B
(Control LAN)