Gate Controller

Description

The Gate Controller option enables you to control access to a gate using a
dedicated Series 1000. When the user enters his vehicle number, the gate
controller verifies the number and activates the gate relay.


Transaction
Matching

If you have an existing Series 1000 without the price data format option or wish to
match a Series 1000 with the MPG option, the Gate Controller system can be
configured to match your existing transactions.


Memory Full

The Gate Controller can also be ordered with Memory Full protection disabled.
This means when the system memory is full, new transactions will overwrite the
transactions already in memory. When you select this option, you cannot retrieve
transactions, the only record will be the direct printout copy.


Hours

Description

An Hours option is available for user equipment that is monitored with an hour
meter instead of an odometer. When you select the Hours option, transaction
odometer (ODOM) field becomes C HOURS; in the MPG option, MILES values
are calculated in HOURS and MPG as HPG; in the reasonable odometer option,
ODOM becomes HOURS.



Loadable Base Pump

Description

The Loadable Base Pump option allows the system operator to assign different
starting pump numbers for a site where there is more than one Series 1000. You
can enter a base pump number that is used as the number of the first pump in a
system. All pumps are numbered consecutively beginning with the base pump
number. The maximum pump number is 99. Pump numbers that are less than
the base pump number will not be available.

Example:

If the base pump number is loaded as 3, there will not be any pumps numbered 1
or 2 at that Series 1000. When pump number 3 is selected for fueling, the first
relay in that system is activated.

Manual Entry


Description

The Manual Entry option provides an additional field that allows you to request
input, from the Series 1000 user, during the keypad entry process. You can use
this field to record anything from manual oil transactions, department numbers or
trailer numbers.


Requirements

You must specify the field name and size when you place your order. The field
may be up to six digits. The check digit, encoded in the vehicle record, controls
whether the individual user is prompted to enter the manual entry. (For more
information, see Check Digit Code earlier in this section). The manual entry
appears under its own heading in the transaction printouts. Figure 3-14 shows a
manual entry option using DEPT (department number) as the entry.