Gate Controller
Description
The Gate Controller option enables you to control access to a gate using a 
dedicated Series 1000. When the user enters his vehicle number, the gate 
controller verifies the number and activates the gate relay. 
 
Transaction 
Matching 
If you have an existing Series 1000 without the price data format option or wish to 
match a Series 1000 with the MPG option, the Gate Controller system can be 
configured to match your existing transactions. 
 
Memory Full 
The Gate Controller can also be ordered with Memory Full protection disabled. 
This means when the system memory is full, new transactions will overwrite the 
transactions already in memory. When you select this option, you cannot retrieve 
transactions, the only record will be the direct printout copy. 
 
 
Hours
Description
An Hours option is available for user equipment that is monitored with an hour 
meter instead of an odometer. When you select the Hours option, transaction 
odometer (ODOM) field becomes C HOURS; in the MPG option, MILES values 
are calculated in HOURS and MPG as HPG; in the reasonable odometer option, 
ODOM becomes HOURS. 
 
 
 
Loadable Base Pump
Description
The Loadable Base Pump option allows the system operator to assign different 
starting pump numbers for a site where there is more than one Series 1000. You 
can enter a base pump number that is used as the number of the first pump in a 
system. All pumps are numbered consecutively beginning with the base pump 
number. The maximum pump number is 99. Pump numbers that are less than 
the base pump number will not be available. 
Example:
If the base pump number is loaded as 3, there will not be any pumps numbered 1 
or 2 at that Series 1000. When pump number 3 is selected for fueling, the first 
relay in that system is activated. 
Manual Entry
 
Description 
The Manual Entry option provides an additional field that allows you to request 
input, from the Series 1000 user, during the keypad entry process. You can use 
this field to record anything from manual oil transactions, department numbers or 
trailer numbers. 
 
Requirements 
You must specify the field name and size when you place your order. The field 
may be up to six digits. The check digit, encoded in the vehicle record, controls 
whether the individual user is prompted to enter the manual entry. (For more 
information, see Check Digit Code earlier in this section). The manual entry 
appears under its own heading in the transaction printouts. Figure 3-14 shows a 
manual entry option using DEPT (department number) as the entry. 