beautypg.com

Specifications and installation, Hardware specifications – Gasboy 1000 Series Technical Reference Manual User Manual

Page 127

background image

03/07/03

5-1

Section 5

SPECIFICATIONS AND INSTALLATION



HARDWARE SPECIFICATIONS

Dimensions:

Total height with post - 60" Cabinet head dimensions - 15"W x 12"H x 20"D


Weight:

Approximately 200 lbs. (Shipping Weight)


Power
Requirements:

115 VAC + 10%, 47-63HZ, 135 watts maximum (all heaters on).


Environmental
Requirements

-30

o

C to 50

o

C, 95% relative humidity, non-condensing.


Lighting:

Faceplate is lit via standard fluorescent tube


Approvals:

FCC and UL


Pump Control
Capacity:

Standard system controls 2 hose outlets (pumps or dispensers), expandable in 2
hose increments to control a total of 8 outlets. Maximum pump load at 3/4 HP,
115 VAC or 230 VAC, 2 solid state relays per hose. Pump loads above 3/4 HP
require external relay.


Pulser Capacity:

Dollar (one pulse per penny) and quantity (1:1, 10:1, 100:1, 250:1, 500:1, 1000:1
pulses per unit of product). Resolution to .001 gallons or liter.

4,200 pulses/minute maximum - Reed Type Pulser

71,000 pulses/minute maximum - Electronic Pulser


Controls &
Indicators:

3 x 4 membrane keypad; 20 character .5" LCD display; Insertion type mag or
optical card reader (Card system); 1 or 2 key receptacles (FleetKey system);
Emergency stop switch; Full manual override switches


Receipt Printer

:

Serial, impact dot matrix printer, 40 columns, 12 CPI, character size 5 x 9 dots


Memory:

32K RAM, battery backed (5 year retention), 8K battery-backed.


Clock:

Real time, battery backed


Communication:

2 asynchronous ports, either may be set for RS-232 or RS-422.

Baud Rates:

300, 600, 1200*, 2400, 4800, 9600 (*Do not exceed 1200 when

polling data from a computer).

Optional:

Auxiliary asynchronous ports which may be set for RS-232 or RS-422

for tank monitor or receipt printer. Baud rates 300, 1200, 9600.


Modems:

Optional built-in, or external


Protection:

Transient protection provided on AC power input and RS-422 communication; Fail
safe protection on pump control drives; AC and DC power fail detect; Missing
Pulse detector


Diagnostics:

Built-in software and hardware diagnostics