Specifications and installation, Hardware specifications – Gasboy 1000 Series Technical Reference Manual User Manual
Page 127

03/07/03
5-1
Section 5
SPECIFICATIONS AND INSTALLATION
HARDWARE SPECIFICATIONS
Dimensions:
Total height with post - 60" Cabinet head dimensions - 15"W x 12"H x 20"D
Weight:
Approximately 200 lbs. (Shipping Weight)
Power
Requirements:
115 VAC + 10%, 47-63HZ, 135 watts maximum (all heaters on).
Environmental
Requirements
-30
o
C to 50
o
C, 95% relative humidity, non-condensing.
Lighting:
Faceplate is lit via standard fluorescent tube
Approvals:
FCC and UL
Pump Control
Capacity:
Standard system controls 2 hose outlets (pumps or dispensers), expandable in 2
hose increments to control a total of 8 outlets. Maximum pump load at 3/4 HP,
115 VAC or 230 VAC, 2 solid state relays per hose. Pump loads above 3/4 HP
require external relay.
Pulser Capacity:
Dollar (one pulse per penny) and quantity (1:1, 10:1, 100:1, 250:1, 500:1, 1000:1
pulses per unit of product). Resolution to .001 gallons or liter.
4,200 pulses/minute maximum - Reed Type Pulser
71,000 pulses/minute maximum - Electronic Pulser
Controls &
Indicators:
3 x 4 membrane keypad; 20 character .5" LCD display; Insertion type mag or
optical card reader (Card system); 1 or 2 key receptacles (FleetKey system);
Emergency stop switch; Full manual override switches
Receipt Printer
:
Serial, impact dot matrix printer, 40 columns, 12 CPI, character size 5 x 9 dots
Memory:
32K RAM, battery backed (5 year retention), 8K battery-backed.
Clock:
Real time, battery backed
Communication:
2 asynchronous ports, either may be set for RS-232 or RS-422.
Baud Rates:
300, 600, 1200*, 2400, 4800, 9600 (*Do not exceed 1200 when
polling data from a computer).
Optional:
Auxiliary asynchronous ports which may be set for RS-232 or RS-422
for tank monitor or receipt printer. Baud rates 300, 1200, 9600.
Modems:
Optional built-in, or external
Protection:
Transient protection provided on AC power input and RS-422 communication; Fail
safe protection on pump control drives; AC and DC power fail detect; Missing
Pulse detector
Diagnostics:
Built-in software and hardware diagnostics