Dimensions:
Total height with post - 60" Cabinet head dimensions - 15"W x 12"H x 20"D
 
Weight: 
Approximately 200 lbs. (Shipping Weight)
 
Power 
Requirements: 
115 VAC + 10%, 47-63HZ, 135 watts maximum (all heaters on).
 
Environmental 
Requirements 
-30
o
C to 50
o
C, 95% relative humidity, non-condensing.
 
Lighting: 
Faceplate is lit via standard fluorescent tube
 
Approvals: 
FCC and UL
 
Pump Control 
Capacity: 
Standard system controls 2 hose outlets (pumps or dispensers), expandable in 2 
hose increments to control a total of 8 outlets. Maximum pump load at 3/4 HP, 
115 VAC or 230 VAC, 2 solid state relays per hose. Pump loads above 3/4 HP 
require external relay. 
 
Pulser Capacity: 
Dollar (one pulse per penny) and quantity (1:1, 10:1, 100:1, 250:1, 500:1, 1000:1 
pulses per unit of product). Resolution to .001 gallons or liter. 
4,200 pulses/minute maximum - Reed Type Pulser
71,000 pulses/minute maximum - Electronic Pulser
 
Controls & 
Indicators: 
3 x 4 membrane keypad; 20 character .5" LCD display; Insertion type mag or 
optical card reader (Card system); 1 or 2 key receptacles (FleetKey system); 
Emergency stop switch; Full manual override switches 
 
Receipt Printer
:
Serial, impact dot matrix printer, 40 columns, 12 CPI, character size 5 x 9 dots
 
Memory: 
32K RAM, battery backed (5 year retention), 8K battery-backed.
 
Clock: 
Real time, battery backed
 
Communication: 
2 asynchronous ports, either may be set for RS-232 or RS-422.
Baud Rates:
300, 600, 1200*, 2400, 4800, 9600 (*Do not exceed 1200 when
polling data from a computer).
Optional:
Auxiliary asynchronous ports which may be set for RS-232 or RS-422
for tank monitor or receipt printer. Baud rates 300, 1200, 9600.
 
Modems: 
Optional built-in, or external
 
Protection: 
Transient protection provided on AC power input and RS-422 communication; Fail 
safe protection on pump control drives; AC and DC power fail detect; Missing 
Pulse detector 
 
Diagnostics: 
Built-in software and hardware diagnostics