Inactivate Pump

The system operator can turn off any pump (hose), currently in use, from a data
terminal by using the IP command. The pump is inactivated only for that
transaction and the message TTY CMD is placed in the ERROR field for that
transaction.


Pump Enable and Disable Via Terminal

Description

Through a data terminal, the system operator can enable (EP) or disable a pump
(DP) from further use. With the DP command, a PUMP DISABLED notation
appears for that pump in the pump status (PP command) printout. The pump
remains disabled until the system operator re-enables it through the data terminal.


Automatic Pump Disable

Description

As a safeguard against defective pulse transmitters in the pumps, the system
operator may configure the system to automatically disable a pump after a
number (1-99) of consecutive no quantity transactions. If a pump becomes
disabled in this manner, a PUMP # X DISABLED message appears on the direct
printout. The pump remains disabled until the system operator re-enables it
through the data terminal.


Automatic Site Shutdown Via Terminal

Description

The system operator can set a time period each day when the system is
automatically shut down and all users are denied access to the fuel dispensing
equipment. A SITE IS DOWN message appears on the system’s LCD display.
The system operator still may access the other software features and may
activate a pump for one transaction through the Activate Pump Feature. The
automatic site shutdown can be disabled through the data terminal.


Odometer/Hours Entry

Description

This feature uses the manual entry check digit entered into the vehicle record, to
determine whether the user is prompted to enter an odometer/hours reading at
the Series 1000 keypad.


Dual Port

Description

This feature allows the system to be connected to two terminal devices or a
terminal and a modem. The system can communicate through only one port at a
time.