2.

Figure out the number of ROM bytes used. Scan the list of options. When you locate an
option in your system, copy the number from the bytes column into the calculation column.
Add the STANDARD DEDUCTION and the OPTION values selected. Then add any
applicable numbers from the COMBINATIONS section. This will equal your ROM Total.


STANDARD DEDUCTION

25136

OPTION

BYTES

+


Receipt

Printer

3176

Multiple Receipts

116

Manual

Entry

282

Activate Pump w/Data Entries

291

MPG/HPG w/Reasonable Odometer

2919

Reasonable Odometer/Hours Only

1603

Fuel

Allocation

1499

Dual

Lockout

144

Loadable Base Pump

238

Multi-Level

Password

557

Supervisor

Cards

834

Fuel Delivery and Dipstick

653

Tank

Monitor

387

Extended Pump Timeouts

102

Pump Switch Timer

417


COMBINATIONS (Add if your system has any of these)


Receipt

Printer

and

MPG/HPG

111

and manual entry

22

and loadable base pump

11

and fuel delivery and dipstick

27

Activate Pump w/Data Entries

and manual entry

61

and

MPG/HPG

258

and reasonable odom/hours

221

and fuel allocation

232

and dual lockout

39

MPG/HPG where VEH # is manual entry

42

Reasonable Odom/Hours where VEH # is manual entry

20

Dual

Lockout

is on manual entry field

49


ROM

Total

=