Gasboy 1000 Series Technical Reference Manual User Manual
Page 119

FleetKey Systems
03/07/03
4-27
Sample receipt
Receipts issued from the Series 1000 contain the following data:
Supervisor Key
Description
This option allows the system operator to use a specially encoded supervisor key
to manually enter ID field information at the Series 1000 keypad. Supervisor keys
are typically used when a key has been lost.
Supervisor fields can be encoded onto key types 1, 2 or 3 and consist of special
characters to designate the supervisor fields. The method for inserting these
special characters varies by key type. For key type 3, press CLEAR twice. The
field is filled with dots. For key types 1 and 2, press CLEAR three times to display
the dots. You can alternate among clear display and dots by repeatedly pressing
the CLEAR button; key types 1 and 2 also have a field separator character. Press
ENTER to go on to the next field.
Maintenance
restriction
Keys to be used with the Maintenance option cannot contain supervisor
characters in the VEH field.
Tank Monitor
Description
The Tank Monitor option enables the system operator to communicate with a
Veeder Root TLS tank monitoring system using the Series 1000 as an interface.
Once the communications link is established, commands issued from the Series
1000 data terminal are passed to the tank monitor and data output from the tank
monitor appears at the Series 1000 data terminal. This interface is completely
transparent except for the ENQ character which terminates the tank monitor
interface. The ENQ character is generated by pressing CTRL E. This option
requires the use of the optional auxiliary communications port PCB.