beautypg.com

Gasboy 1000 Series Technical Reference Manual User Manual

Page 122

background image

GASBOY Series 1000

4-30

03/07/03

2.

Figure out the number of ROM bytes used. Scan the list of options. When you locate an
option in your system, copy the number from the bytes column into the calculation column.
Add the STANDARD DEDUCTION and the OPTION values selected. Then add any
applicable numbers from the COMBINATIONS section. This will equal your ROM Total.


STANDARD DEDUCTION

31299

OPTION

BYTES

+


Receipt

Printer

2663

Multiple Receipts

116

Manual

Entry

152

Lockout on Manual Entry

345

Activate Pump w/Data Entries

233

MPG

History

1873

Fuel

Allocation

1820

Maintenance

2621

Encoding

2310

Off-Site Fueling Transactions

634

Loadable Base Pump

242

Multi-Level

Password

582

Supervisor

Key

614

Delivery and Dipstick

595

Tank Monitor Interface

410

Extended Pump Timeouts

100

Pump Switch Timer

454

Fuel

Point

2786


COMBINATIONS (Add if your system has any of these)


Receipt

Printer

and manual entry

22

and off-site fueling

22

and loadable base pump

11

and AP w/data entries

4

and delivery and dipstick

27

and

supervisor

-54

Activate Pump w/Data Entries

and manual entry

8

and lockout on manual entry

57

and

allocation

235

and MPG history

108

Encoding

and Supervisor key

213

and delivery and dipstick

-8

Off-Site Fueling Transactions

and AP w/data entries

-83

and manual entry

21

and AP/data entries and manual entry

-15

and MPG history

217

Subtotal of this page