Gasboy 1000 Series Technical Reference Manual User Manual
Page 122

GASBOY Series 1000
4-30
03/07/03
2.
Figure out the number of ROM bytes used. Scan the list of options. When you locate an
option in your system, copy the number from the bytes column into the calculation column.
Add the STANDARD DEDUCTION and the OPTION values selected. Then add any
applicable numbers from the COMBINATIONS section. This will equal your ROM Total.
STANDARD DEDUCTION
31299
OPTION
BYTES
+
Receipt
Printer
2663
Multiple Receipts
116
Manual
Entry
152
Lockout on Manual Entry
345
Activate Pump w/Data Entries
233
MPG
History
1873
Fuel
Allocation
1820
Maintenance
2621
Encoding
2310
Off-Site Fueling Transactions
634
Loadable Base Pump
242
Multi-Level
Password
582
Supervisor
Key
614
Delivery and Dipstick
595
Tank Monitor Interface
410
Extended Pump Timeouts
100
Pump Switch Timer
454
Fuel
Point
2786
COMBINATIONS (Add if your system has any of these)
Receipt
Printer
and manual entry
22
and off-site fueling
22
and loadable base pump
11
and AP w/data entries
4
and delivery and dipstick
27
and
supervisor
-54
Activate Pump w/Data Entries
and manual entry
8
and lockout on manual entry
57
and
allocation
235
and MPG history
108
Encoding
and Supervisor key
213
and delivery and dipstick
-8
Off-Site Fueling Transactions
and AP w/data entries
-83
and manual entry
21
and AP/data entries and manual entry
-15
and MPG history
217