Optical card systems – Gasboy 1000 Series Technical Reference Manual User Manual
Page 60

GASBOY Series 1000
2-42
03/07/03
Optical Card Systems
NOTE: These calculations do not apply to "A" Systems. For "A" System optical cards, see the
Supplemental "A" System Order Form.
1. Figure out the number of bytes in the transaction record. Only add in the calculations for
manual entry, MPG/HPG, and receipt printer if you have these options.
Field 1
(_____
digits
+
1)
/
2 (drop decimal remainder)
=
Field 2
(_____
digits
+
1)
/
2 (drop decimal remainder)
=
Manual Entry
(_____ digits
+
1)
/
2 (drop decimal remainder)
=
MPG/HPG
Add
2
=
Receipt Printer
Add 1
=
+
22
Number of Bytes in Transaction Record (Add column)
=
2.
Figure out the number of ROM bytes used. Scan the list of options. When you locate an
option in your system, copy the number from the bytes column into the calculation column.
Add the STANDARD DEDUCTION and the OPTION values selected. Then add any
applicable numbers from the COMBINATIONS section. This will equal your ROM Total.
STANDARD DEDUCTION
22844
OPTION
BYTES
+
Receipt
Printer
3171
Multiple Receipts
116
Manual
Entry
282
Activate Pump w/Data Entries
290
MPG/HPG w/Reas. Odom/Hours
2919
Reasonable Odom/Hours Only
1603
Fuel
Allocation
1507
Dual
Lockout
147
Loadable Base Pump
238
Multi-Level
Password
557
Supervisor
Cards
461
Fuel Delivery and Dipstick
653
Tank
Monitor
387
Extended Pump Timeouts
102
Pump Switch Timer
417