Gasboy cfn series compatibility - summary – Gasboy 1000 Series Technical Reference Manual User Manual
Page 31

Card Systems
03/07/03
2-13
GASBOY CFN SERIES COMPATIBILITY - SUMMARY
As noted throughout this section, Series 1000 cards can be configured to be
compatible with some GASBOY CFN Series Systems. This option must be
specified at the time of order. The following chart summarizes the restrictions that
apply to CFN cards that will be used with a Series 1000:
System ID
4-6 digits long
Lockout Field
Card number (First 4 digits of CFN Account field)
Dual Lockout
Optional second lockout field must be 4-digits long. The
Series 1000 does not provide lockout capability for fields over
4-digits long.
Account Field
The Series 1000 will only use 16 digits of the Account field.
The Account field may be up to 20 digits long, but the last four
digits will be ignored.
Bank Cards
Not accepted by the Series 1000.
Expiration Date
Not a required field.
Product Limitation
Must be present and may be 1- or 2-digits long. If the 2-digit
limitation code is chosen, it is converted internally to a
corresponding Series 1000 1-digit code. If the first digit is 0,
the product limitation is determined by the second digit. If the
first digit is not 0, limitation code 9 is used. (Examples: 01=1,
04=4, 11=9, 23=9).
Product Authorization
Must be present and may be 1- or 2-digits long. If the 2-digit
authorization code is chosen, it is converted internally to a
Series 1000 1-digit code. If the first digit is 0, the product
authorization is determined by the second digit. If the first digit
is not 0, all fuels are allowed. (Examples: 01=1, 05=5, 11=0,
23=0).
Price Level
Is read, but ignored.
Check Digit
Must be 1-digit. If the check digit appears on both cards, in a
dual card system, it must be the same on both cards.
Max digits on card
33 for mag card and 20 for optical card.