Gasboy 1000 Series Technical Reference Manual User Manual
Page 109

FleetKey Systems
03/07/03
4-17
Inactivate Pump
The system operator can turn off any pump (hose), currently in use, from a data 
terminal by using the IP command. The pump is inactivated only for that 
transaction and the message TTY CMD is placed in the ERROR field for that 
transaction. 
 
 
Pump Enable and Disable Via Terminal
Description
Through a data terminal, the system operator can disable a pump (DP command) 
from further use. A PUMP DISABLED notation appears for that pump in the 
pump status (PP command) printout. The pump remains disabled until the 
system operator re-enables it through the data terminal. 
 
 
Automatic Pump Disable
Description
As a safeguard against defective pulse transmitters in the pumps, the system 
operator may configure the system to automatically disable a pump after a 
number (1-99) of consecutive no quantity transactions. If a pump becomes 
disabled in this manner, a PUMP # X DISABLED message appears on the direct 
printout. The pump remains disabled until the system operator re-enables it 
through the data terminal. 
 
 
Automatic Site Shutdown Via Terminal
Description
The system operator can set a time period each day when the system is 
automatically shut down and all users are denied access to the fuel dispensing 
equipment. A SITE IS DOWN message appears on the system’s LCD display. 
The system operator still may access the other software features and may 
activate a pump for one transaction through the Activate Pump Feature. The 
automatic site shutdown can be disabled through the data terminal. 
 
 
Odometer Entry/Reasonable Odometer
Description
This feature uses the manual entry check digit encoded on the card to determine 
whether the user is prompted to enter an odometer reading at the Series 1000 
keypad. This feature can also be ordered to prompt for hours for users 
measuring fuel consumption via an hour meter. See the Hours option under 
Optional System Features. 
The FleetKey system also provides a reasonability check for odometers entered. 
If you use this feature, you must include a reasonableness check digit on your 
key. The check digit (0-2) determines what action is to be taken on the entered 
odometer. 0 allows any odometer entry; 1 checks for reasonability, prompts for 
retries, and allows fuelings; 2 requires reasonability, denies fueling if odometer is 