7-7 Storage Disk Maintenance
1. Connect to the admin interface using your preferred connection mechanism. See
.
2. Login as admin.
3. Select the Disk Check link in the Configuration menu; the disk maintenance page opens.
4. Click the Check Now button; a new page opens showing you the progress of the disk check.
Do not interrupt power to the system during the disk check.
5. When the disk check is complete, the main page returns and a summary is shown.
6. If any unrecoverable errors are detected, contact Epiphan support.
Rebuild or replace storage disks
The rackmount Networked VGA Grid can be optionally configured with storage configured in a RAID array.
Periodically you may wish to clean the RAID array to start from scratch, or you may want to introduce new disks
in place of the old ones.
When working with RAID arrays it is important to keep the disks in sets that contain the same data so the RAID
will continue to perform. For that reason you should name your disk sets, i.e. set A, set B, etc.