Chapter 3 Connections and Wiring|ASDA-B Series
3-18
Revision February 2008, Doc. Name: 2006PDD23000009
3.3.3 User-defined DI and DO signals
If the default DI and DO signals could not be able to fulfill the users’ requirements, there are still user-
defined DI and DO signals. The setting method is easy and they are all defined via parameters. The
user-defined DI and DO signals are defined via parameters P2-10 to P2-15 and P2-18 to P2-20.
Please refer to the following Table 3.G for the settings.
Table 3.G User-defined DI and DO signals
Signal Name
Default Pin
No.
Parameter
Signal Name
Default Pin
No.
Parameter
DI1- 17
P2-10
DO1+
16
P2-18
DI2- 18
P2-11
DO2+
2
P2-19
DI3- 5
P2-12
DO
DO3+
1 P2-20
DI4- 3
P2-13
DI5- 15
P2-14
DI
DI6- 14
P2-15
DI signal:
For example: If the users want to set DI1 to be servo on, it only needs to set the value of parameter P2-
10 to 101 (refer to chapter 7).
NOTE
1) 14~17: Single control mode;18~20: Dual control mode; 0: Input function disabled
Setting of parameter P2-10 to P2-15:
DI Code
Signal
Description
01 SON
Servo
On
02 ARST
Alarm
Reset
03
GAINUP
Gain switching in speed and position mode
04 CCLR
Pulse
clear
05 ZCLAMP
Zero
speed
CLAMP
06
CMDINV
Command input reverse control
07
INHP
Pulse inhibit input
09
TRQLM
Torque limit enabled
10
SPDLM
Speed limit enabled
11
GNUM0
Electronic gear ratio (Numerator) selection 0
14
SPD0
Speed command selection 0
15
SPD1
Speed command selection 1
16
TCM0
Torque command selection 0
17
TCM1
Torque command selection 1
18
S-P
Position / Speed mode switching (OFF: Speed, ON: Position)