Chapter 3 Connections and Wiring|ASDA-B Series

3-18

Revision February 2008, Doc. Name: 2006PDD23000009

3.3.3 User-defined DI and DO signals

If the default DI and DO signals could not be able to fulfill the users’ requirements, there are still user-

defined DI and DO signals. The setting method is easy and they are all defined via parameters. The

user-defined DI and DO signals are defined via parameters P2-10 to P2-15 and P2-18 to P2-20.

Please refer to the following Table 3.G for the settings.

Table 3.G User-defined DI and DO signals

Signal Name

Default Pin

No.

Parameter

Signal Name

Default Pin

No.

Parameter

DI1- 17

P2-10

DO1+

16

P2-18

DI2- 18

P2-11

DO2+

2

P2-19

DI3- 5

P2-12

DO

DO3+

1 P2-20

DI4- 3

P2-13

DI5- 15

P2-14

DI

DI6- 14

P2-15

DI signal:

For example: If the users want to set DI1 to be servo on, it only needs to set the value of parameter P2-

10 to 101 (refer to chapter 7).

NOTE

1) 14~17: Single control mode;18~20: Dual control mode; 0: Input function disabled

Setting of parameter P2-10 to P2-15:

DI Code

Signal

Description

01 SON

Servo

On

02 ARST

Alarm

Reset

03

GAINUP

Gain switching in speed and position mode

04 CCLR

Pulse

clear

05 ZCLAMP

Zero

speed

CLAMP

06

CMDINV

Command input reverse control

07

INHP

Pulse inhibit input

09

TRQLM

Torque limit enabled

10

SPDLM

Speed limit enabled

11

GNUM0

Electronic gear ratio (Numerator) selection 0

14

SPD0

Speed command selection 0

15

SPD1

Speed command selection 1

16

TCM0

Torque command selection 0

17

TCM1

Torque command selection 1

18

S-P

Position / Speed mode switching (OFF: Speed, ON: Position)