beautypg.com

Delta Electronics AC Servo Drive ASDA-B User Manual

Page 185

background image

Chapter 7 Servo Parameters|ASDA-B Series

7-32

Revision February 2008, Doc. Name: 2006PDD23000009

P1 - 33

Reserved

Communication Addr.: 0121H

P1 - 34

TACC Acceleration Time

Communication Addr.: 0122H

Default: 200

Related Section:

Applicable Control Mode: S

P1-35, P1-36, Section 6.3.3

Unit: ms

Range: 1 ~ 20000

Settings:

It is used to determine the acceleration time to accelerate from 0 to its rated rotation speed.
(When P1-36 is set to 0: Accel/Decel function is disabled, i.e. P1-34, P1-35 is disabled)

P1 - 35

TDEC Deceleration Time

Communication Addr.: 0123H

Default: 200

Related Section:

Applicable Control Mode: S

P1-34, P1-36, Section 6.3.3

Unit: ms

Range: 1 ~ 20000

Settings:

It is used to determine the deceleration time to decelerate from its rated rotation speed to 0.
(When P1-36 is set to 0: Accel/Decel function is disabled, i.e. P1-34, P1-35 is disabled)

P1 - 36

TSL

Accel /Decel S-curve

Communication Addr.: 0124H

Default: 0

Related Section:

Applicable Control Mode: S

P1-34, P1-35, Section 6.3.3

Unit: ms

Range: 0 ~ 10000 (0: Disabled)

Settings:

This parameter is used to make the motor run more smoothly when startup and windup.

Using this parameter can improve the motor running stability.

Time
(ms)

Speed

TSL/2

TACC

TSL/2

TSL/2

TDEC

TSL/2

TSL: P1-36, Accel /Decel S-curve

Total acceleration time = TACC + TSL

TACC: P1-34, Acceleration time

Total deceleration time = TDEC + TSL

TDEC: P1-35, Deceleration time