Chapter 12 Application Examples |ASDA-B Series

Revision February 2008, Doc. Name: 2006PDD23000009

12-5

ASDA-B series Servo Drive

1. When using open-collector input, the max. allowable input pulse frequency is 200Kpps.

2. Parameter

Settings:

„

Set P1-01=06 (S-T dual mode)

„

Set P1-09 ~ P1-11 (Internal speed command)

„

Set P1-36=1 (Accel /Decel S-curve)

„

Set P2-10=101 (DI1=Servo On)

„

Set P2-11=104 (DI2=CCLR)

„

Set P2-12=114 (DI3=SPD0)

„

Set P2-13=115 (DI4=SPD1)

„

Set P2-14=118 (DI5=S-P dual mode switching)

„

Set P2-32=1 (PDFF, the ratio of load inertia to servo motor inertia can be continuously adjusted.)

3. Communication format: Both DVP-EH series PLC and ASDA-B series servo drive have to use the

same communication protocol setting.