Chapter 7 Servo Parameters|ASDA-B Series

Revision February 2008, Doc. Name: 2006PDD23000009

7-17

Others

Control

Mode

Parameter

Name

Function

Default

Unit

P

S

T

P1-32

LSTP

Motor Stop Mode Selection

0

N/A

{

{

{

P1-37 GDR

Ratio of Load Inertia to Servo Motor
Inertia

10

0.1

times

{

{

{

P1-52

RES1

Regenerative Resistor Value

40

Ohm { {

{

P1-53 RES2

Regenerative

Resistor

Capacity

60 Watt

{

{

{

P2-08■

PCTL

Special Factory Setting

0 N/A

{

{

{

P2-30■

INH

Auxiliary Function

0 N/A

{

{

{

P2-34

SDEV

Overspeed Warning Condition

5000

rpm

{

P2-35

PDEV

Excessive Error Warning Condition

3000

10pls {

P2-36

OVL

Overload Protection Level

100

%

{

{

{

P2-37

OVW

Output Overload Warning Level

50%

N/A

{

{

{

P2-38 GBIT

Special

Function

0 N/A

{

{

{






















Explanation of symbols (marked after parameter)
(★) Read-only

register.

(▲)

Parameter cannot be set when Servo On (when the servo drive is enabled).

(●)

Parameter is effective only after the servo drive is restarted (after switching power off and on).

(■)

Parameter setting values are not retained when power is off.