Chapter 7 Servo Parameters|ASDA-B Series

7-20

Revision February 2008, Doc. Name: 2006PDD23000009

NOTE

1) When this fault occurs, users can use ARST signal to clear the fault message.

2) This fault can be cleared automatically when users eliminate the error source. Using ARST

signal can not clear this fault message.

3) This fault can not be cleared even if users eliminate the error source. Users must restart the

servo drive (after switching power off and on) and then the fault can be cleared.

4) When this fault occurs, it indicates the internal EEPROM may be damaged and using ARST

signal can not clear this fault message.

The fault display shown on PC-Based communication software and Keypad:

Settings:

1 : Overcurrent

2 : Overvoltage

3 : Undervoltage

4 : Z Pulse shift

5 : Regeneration error

6 : Overload

7 : Overspeed

8 : Abnormal pulse control command

9 : Excessive deviation

10 : Serial communication error

11 : Encoder error (Position detector fault)

12 : Adjustment error

13 : Emergency stop

14 : Reverse (CWL) limit error

15 : Forward (CCWL) limit error

16 : IGBT temperature error

17 : Memory error

18 : Serial communication time out

19 : Motor type error

20 : Input power phase loss