beautypg.com

4 remote interface, 1 host computer remote communications, 6 remote port test – Comtech EF Data RCS20 User Manual

Page 97: 1 programming steps

background image

RCS20 M:N Redundancy Switch

Revision 15

User Interfaces

MN-RCS20 and CD-RCS20

4–63

4.3.4.6 REMOTE PORT TEST

This screen allows the user to send an ASCII test string out of the remote port.

4.3.4.6.1 Programming steps:

1.

Press to send an ASCII string. The RCS20 will output ASCII characters ‘Test’ via remote
port each time is pressed.

Key

Label

Function

S1

TEST

Press to send ASCII characters ‘Test’.

S2

---

N/A

S3

---

N/A

S4

RETURN Press to cycle back to the SWITCH SYSTEM TESTS Screen 2.

Numeric Keypad ---

N/A

4.4 Remote Interface

4.4.1 Host Computer Remote Communications

The RCS20 has a dedicated RS-485 serial control port (Remote Port) for use with computer controlled
remote monitor and control systems. The Remote Port is a 9-Pin female ‘D’ sub connector J3 located at
the rear of the unit on the Switch Interface plug in module. The pinouts for the remote port are listed in
Section 5.

The Remote Port utilizes a binary protocol called Radyne Link Level Protocol (RLLP). RLLP is a multi-
drop packet-oriented protocol with handshaking, and is completely described in Appendix A. The remote
port supports standard UART asynchronous protocol with 8 data bits, no parity, and 1 stop bit (8N1) at 8
baud rates: 115200, 57600, 38400, 19200, 9600, 4800, 2400, and 1200.

REMOTE PORT TEST

Remote test will send ASCII characters ‘Test’ to remote port

each time the softkey labeled ‘Test’ is pressed.