background image

RCS20 M:N Redundancy Switch

Revision 15

Electrical Interfaces

MN-RCS20 and CD-RCS20

5–26

5.5.1.1.7 J7 | UP6

The J7 | UP6 port is used for connecting satellite transmission channel 6 to an up converter or combiner.

5.5.1.1.8 J8 | UP7

The J8 | UP7 port is used for connecting satellite transmission channel 7 to an up converter or combiner.

5.5.1.1.9 J9 | UP8

The J9 | UP8 port is used for connecting satellite transmission channel 8 to an up converter or combiner.

5.5.1.1.10 J10 | MOD TEST 2

The J10 | MOD TEST (Modulator Test) 2 port is a troubleshooting utility port used to inspect the output of
a failed prime that is being backed up by channel 1.

5.5.1.1.11 J12 | MOD TEST 1

The J12 | MOD TEST (Modulator Test) 1 port is a troubleshooting utility port used to inspect the output of
a failed prime that is being backed up by channel 1.

5.5.1.1.12 J24 | DN AUX 2

The J24 | DN AUX 2 port is used for factory test only.

5.5.1.1.13 J25 | DN AUX 1

The J25 | DN AUX 1 port is used for connecting a down converter or splitter for satellite receive channel 9
in a 1:9 system.

5.5.1.1.14 J26 | DN 1

The J26 | DN1 port is used for connecting a down converter or splitter for satellite receive channel 1.

5.5.1.1.15 J27 | DN2

The J27 | DN2 port is used for connecting a down converter or splitter for satellite receive channel 2.

5.5.1.1.16 J28 | DN3

The DN3 port is used for connecting a down converter or splitter for satellite receive channel 3.