RCS20 M:N Redundancy Switch

Revision 15

User Interfaces

MN-RCS20 and CD-RCS20

4–30

Key

Label

Function

S3

---

N/A

S4

RETURN Press to return to the AUTO MODE BACKUP ASSIGNMENT SUMMARY Screen.

Numeric Keypad ---

Used to enter the prime channel number to switch to Backup Channel 2.
Press or to abort programming (no switch parameters changed).
Press to load the information on the screen into the switch parameter table.
Switching will occur immediately after pressing .

4.3.2 CONFIG SYSTEM Menu Tree

4.3.2.1 CONTROL MODE CONFIGURATION

This screen allows the user to modify the control mode. The Control Mode may be one of the following:

FT PANEL - Front Panel Control - Commands will only be accepted from the front panel and
keypad.

TERM - Remote Terminal Control - Commands will only be accepted through the RS-232
terminal connection.

COMPUTER - Command Interface Control - Commands will only be accepted from the RS-484
remote port connection.

4.3.2.1.1 Programming steps:

1. Press , , or to select the desired control mode. The mode

will be selected immediately after pressing the appropriate key.

Key

Label

Function

S1

FT PANEL

Press to select Front Panel Control.

S2

TERM

Press to select Remote Terminal Control.

S3

COMPUTER Press to select Command Interface Control.

S4

NEXT

Press to cycle to the next screen.

CONTROL MODE CONFIGURATION

CONTROL MODE: FRONT PANEL

NEXT